![]() OS: Windows 10 Pro (64 bit), CPU: 3.70 GHz, RAM: 16.0 GB, USB connections: One NR-X100W (no other USB devices), Ethernet connection: One-to-one connection between NR-X100W and PC Using normal mode and saving in the standard format with a pre-installed OS and running only WAVE LOGGER X. *6 Acquisition from a PC may not be possible in some PC environments. *5 Use is permitted only if the total power consumption of all measurement units, remote units, and environment-resistant measurement units used in the system is 50 W or less when remote units are not connected to an AC adapter. *4 Use is permitted only if the total power consumption of all connected measurement units is 20 W or less. The main unit’s automatic saving function allows data to be saved to an SD card in the main unit even if acquisition by PC stops. Using an onsite local network connection or wireless LAN connection may cause acquisition to stop due to a decrease in transfer speeds caused by network load or wireless LAN communication conditions. When acquiring data from a PC (using WAVE LOGGER X software), use a wired local connection only between the NR-X100W and the PC. *3 Wired LAN and wireless LAN cannot be used at the same time. Using a product not recommended by KEYENCE may result in data not being saved to the SD card during continuous acquisition. *2 Use only products recommended by KEYENCE (CA-SD4G: 4 GB, CA-SD16G: 16 GB). The available data buffer memory per NR-X100W and NR-XR01 group is limited to 25M. *1 Data is not backed up when the power is turned off. Battery operation possible when connected to the NR-XU15 battery power supply unitĨ.4 W or less (excluding connected units)Īpprox.72 W (when connected to DC terminal block at 9 V: 8.0 A or less at 24 V: 3.0 A or less at 36 V: 2.0 A or less) NR-XU1 AC adapter, or 9 to 36 VDC (including ripple) / Max.Judgment output 1 to 4 (OUT1 to 4): N.O.Insulation between output and system bus (500 VDC/1 minute).Leak current at OFF: 0.1 mA or less, Residual voltage when ON: 1 V or less.Maximum rating: 36 VDC, Output current: 50 mA or less (9-point total: 300 mA or less).Program selection input 0 to 3 (PROG IN0 to 3): Level input (only enabled in external control mode).Auto-balance input (BAL): Edge input (only enabled in external control mode). ![]() Acquisition start/stop input (START IN): Level input (only enabled in external control mode).External trigger input (TRG IN): Edge input. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |